Automation - When and Why?
Titration Automation
Metrohm have long been able to perform analyses automatically. However, large sample throughput can only be achieved using an efficient sampler changer system, which suits your throughput, sample size, collection vessel shape, sample preparation and budget.
Often the justification for automating your analysis can be made by 24hr analysis seven days a week, with the payback period being as low as under a year.
- For large numbers of samples
- When a high level of automation is required
- Where sample preparation must be rationalised
- Where there is no time for sample preparation
- Where the highest precision and reproducibility is demanded
- Lower cost analysis
- Greater sensitivity in the detection of end-points through mathematical evaluation
- Error-free documentation of analysis results on-line to LIMS systems
- High sample output
- Reproducible results
- Operator requires no special knowledge
- Operational personnel are freed for the duration of the analysis
- Contact with toxic chemicals is reduced to a minimum
- The system can operate seven days a week for twenty-four hours
| Sample Changer/Processor |
855 Titrosampler |
Robotic Sample Processor 815/789 |
Sample Processor 814/778 |
824 Easy Sample Changer |
| Built-in Titrando titrator, 1 electrode input |
Yes |
|
|
|
| Carousel sample changer with exchangeable sample racks |
Yes |
Yes |
Yes |
Yes |
| Automatic rack recognition |
Yes |
Yes |
Yes |
Yes |
| Optical beaker sensor |
Yes |
Yes |
Yes |
Yes |
| Number of samples in 1 row (75 ml beakers) |
|
|
24 |
24 |
| Number of samples in multiple rows (75 ml beakers) |
100 |
100 |
48 |
|
| Largest possible number of samples (definable positions) |
999 |
999 |
999 |
24 |
| Direct titration in sample beaker |
Yes |
Yes |
Yes |
Yes |
| Titration in external vessel |
Yes |
Yes |
|
|
| Remote connection |
Optional |
Optional |
Optional |
Yes |
| USB connection |
Yes |
815 only |
814 only |
|
| MSB connections (for Dosino, 801/804 stirrer, etc.) |
3 |
3 |
3 |
0 |
| 802/741 Stirrer connections |
1 |
1 |
1 |
1 |
| Connects to tiamo software |
Yes |
Yes |
Yes |
|
| Number of workstations |
1 |
1 or 2 |
1 |
1 |
| Pump connections |
2 |
2/4 |
2 |
2 |
| Liquid handling, transferring, pipetting |
Yes |
Yes |
Yes |
|
| Suitable for KF applications |
Yes |
Yes |
Yes |
Yes |
| Sample racks for customer-specific applications |
Yes |
Yes |
Yes |
|
| Freely programmable sequences via keypad or PC |
Yes |
Yes |
Yes |
|
| Predefined programs |
Yes |
Yes |
Yes |
Yes |
| Max. load on lifting arm |
3 kg |
3 kg |
3 kg |
|
| Max. load on sample rack |
12 kg |
12 kg |
12kg |
|
If you would like to receive the whole automation DVD free of charge then please email enquiry@metrohm.co.uk with your full name and address